Skip to Content

Structural monitoring of a church


 Remote monitoring
 Inclination

 Crack
 Humidity
 Convergence


 

Context & Constraints

This project aims to monitor several sensitive areas of an ancient building in order to ensure the safety of the building and the public.

Detect the movements and evolution of wall cracks, related to the aging of the structure, climatic conditions or phases of work.

PROJECT LIMITATIONS AND CONSTRAINTS

Monitor structural disorders

Measurement of cracks and wall movements.

Monitor the evolution over time

Continuous monitoring over the duration of the works (18 months) with alerts in case of significant movements

Preserve the building and the public

Anticipate any critical degradation and secure this place welcoming visitors.


  Explore our structural monitoring solutions


Project details


Address
Town of Auriol

Design office
DEM engineering

Contractor
Town of Auriol

Website 
https://dem-ingenierie.fr

Objective 
As part of the observation of the evolution of the disorders noted on a chapel located in a municipality near Montpellier, an expert is commissioned to instrument the monitoring of the evolution of the walls, during the work phase over a duration of 18 months.

Four DELTA L type crack gauges equipped with a strain gauge pack have been installed. The objective is to analyse the movement/displacement of the walls throughout the duration of the work intervention.

The sensors are connected remotely and a report will be established every 3 months on the evolution of the walls.

The sensors used for the project

Votre snippet dynamique s’affichera ici... Ce message s’affiche car vous n’avez pas fourni suffisamment d’options pour en récupérer le contenu.